Schematic Diagrams -
Stage Dimensions - Stage
Rigging and Curtains
Stage Lighting Equipment - General
Information - Audio Systems
Schematic Diagrams
Click for a large view
Street Level View
Cross Section View
Light Plot
Download Drawings
Click the links below to download drawing files
Light Plot - DWG - DXF - WYG
Theater Ground Plan - DWG - DXF
Theater Section - DWG - DXF
Stage Dimensions
Proscenium width: 36'
31'6" curtain opening
Proscenium height:
25' to permanent soft teaser
30' to plaster
Distance from Proscenium Wall
to back wall: 35'
to last line set: 29'3"
Distance from back wall to downstage edge: 36'6"
Distance from centerline
to stage left wall(flyrail bumper): 29'
to stage right wall: 31'6"'
Height of grid: 64'
Gallery floors(fly) Stage left and right: 36'
Orchestra Pit (fixed-no lift):
7'6" below stage level(Deep]
15' on CL x 32' wall to organ
Pit extends back under stage 7'6"
from edge of stage at centerline
Orchestra Pit Filler-May be used at house floor or stage
level Theater seating is increased by 32 seats with filler at floor
level.
Stage floor is resilient-suitable for dance
Stage floor has Trap on centerline: 28'2" from stage Apron
Dimensions: 38"x82"
CM 1/2 ton chain hoist from grid
over trap to lower equipment
to basement
Stage Rigging and Curtains
1 House Curtain rigged to fly or travel
-live end stage left
32 4-line J-bar counterweight sets-
rail located stage left
Pipe length is 44 feet
5 Pair black velour legs sewn flat
3 pair-12'x30'
2 pair-15'x30'
1 Black velour full stage back drop 30'x40'
10% fullness with centerline split
2 Sharktooth Scrims
White 30'x44'
Black 30'x44'
Black 32'x44'(has corner tear, is sewn)
2 Cycloramas
Seamed natural muslin 34'x44'
Garriet's plastic bounce 32'x44'
1 Projection Screen(front)-Image area 11'6"x15'7"
Two CD 80 Racks with AMX 192 Protocol
156 2.4K dimmers (Strand CD 80)
4 2.4K non-dims(Strand CD 80)
12 6.0K dimmers(Strand CD 80)
156 20 amp hardwired circuits 1-156
18 50 amp hardwired circuits 157-174
Circuits 1-68 and 147-170 are front of house
circuits that can also be used back stage via a
Transfer panel located down stage right.
This panel can also be used to connect road
boards to FOH circuits
Company switch located down stage right:
400 amp 240 volt 3 phase disconnect
Lighting Control:
ETC Congo lighting console
3072 control channels, 40 multipurpose masters, 40 direct selects,
Control and programming for automated fixtures
2 DMX Universes
Gray Interface DMX to AMX ultimate converter
Lighting Fixtures:
8 CCT 8° 1Kw
22 CCT 10° 1Kw Zoom
18 Strand SL 19° 575 w
8 Strand SL 26° 575 w
4 Strand SL 50° 575 w
2 Strand SL 10° 575 w
1 Strand SL 5 ° 575 w
4 Strand SL 15/32° Zoom 575 w
1 Strand SL 23/50° Zoom 575 w
26 6x16 1Kw
1 6x16 1Kw Iris unit
19 6x16 750 w
9 6x12 1Kw
50 6x12 750 w
38 6x9 750 w
120 Source4 Par 575 w
Have extra lens to swap out: WFL's, NSP's, VNSP's
32 Par 64 1Kw
Have extra bottles to swap out: WFL's, NSP's, VNSP's
6 6" Fresnels 500w
4 R40 Cans 300w floods
10 Colortran 4 cell Cyc striplight(ground row) 1Kw
12 CCT "Minuette" 3 cell cyc striplights 500w
4 CCT "Minuette" single cyc lights 500w
12 Strand "Ianiro Iris" 2 cell Far Cycs 1Kw
2 Lyceum 1267 Super Arc 400 Follow Spot 8 50# Bases with a variety of
pipe lengths
53 Side Arms
6 10' Triangular Truss Section
Three sections are used for upstage for cyc lights
8 4-Rung Ladders
Cable, two-fers, and mults to facilitate most productions
Loading door is upstage left of centerline
10' wide x 8'6" high
(Small items can be loaded-in through front
Atrium/Stagedoor on House left/stage right)
3 Dressing rooms with 2 make-up stations
[1A, 2A, 3A]
2 Dressing rooms with 6 make-up stations
[2B, 3B]
3 Showers located on Level 4(can be used as dressing rooms if needed)
Toilet facilities located on Lower level
Greenroom and Rehearsal room located on Lower level
Rehearsal room has 2 make-up stations. This room can be used for chorus
dressing room, catering, production offices.
Theater has 4 control Areas/rooms:
Lighting/Broadcast/Audio(main floor control room):
Control is a Strand Series 300 console with 24 Submasters and Remote.
Other control locations for lighting are Main Floor Center in house
Stage right or left at SM console. This control room has Audio &
Video tie lines. It has mic/tie lines to various locations in building(i.e.,
loading dock) and to Minnesota Public Radio for broadcast and/or Multi-track
recordings
Patching is through TT Jackfield Also has space for audio, video control
and projection equipment as needed. Projection distance to Bijou screen
63'8" min to 65'8" max
Followspot Booth(located in ceiling):
2-Lyceum 1267 Super Arc 400 Spot
Has audio/video tie lines
House Sound Reinforcement(located at front
of 1st balcony house right):
Has a duplicate TT Jackfield of Main
control room. Has video tie line
Stage Manager Console(downstage right):
Has time clock, countdown clock, Clear-Com master station, page, chimes,
Shure mixer, audio/video tie lines, AM/FM Tuner, Sony CD Player
This console can be remoted to stage left
Video: Coaxial cables with BNC connectors are available
at all Control Areas, stage right & left,
upstage right, upstage center by dock cable conduits, greenroom, rehearsal
room
Power Available 240 VAC:
400 amp 3 phase Company switch stage right
200 amp 3 phase switch located on loading dock ` for Production Trucks
Two 400 amp 3 phase switches on fly floors(5th) on stage right. These
are available only if not using Stage dimming system(CD-80 Racks)
Camera Kill Seats:
3 on Main floor
[Center-Rows "M & N" Seats 8,9,10,11,12,13"]
[Right-Rows "M & N" Seats "1,2"]
[C, R, L-Row "G" for tracking camera]
1st Balcony
[Right-Rows "AA & BB" Seats "1,2,3,4"]
Sound Kill Seats:
Center Section, Row [M & N" seats"8,9,10,11,12,13]
This creates a space of 6'x10'
4" cable conduits from backstage to 1st & 2nd balconies
on stage left and right
6" & 8" cable conduits to stage from loading dock
Platforms:
5- 4' x 8' x 24"
3- 4' x 8' x 16"
3- 4' x 8' x 8"
2- 3' x 6' x 16"
2- 4' x 6'x 24"
2- 4' x 6'x 16"
2- 4' x 6'x 8"
2- 4' x 8'x 30" to 4'
2 sets of pies, trapezoids to do corners & bends
Choral Risers: 5- three step units
Orchestra Chairs: 71
Black Stacking Chairs 60
Music Stands-: 43
One 24' Genie Personal Lift [battery]
CM 1/2 Ton Motor w/Bag;
Inverted with 60' chain with Control/Power Cable
CM 1/2 Ton Motor w/Bag Double purchase
used over trap to lower equipment to basement
House Mixing Console: Avid Venue Mix Rack System
48 Patchable Input Channels
16 Patchable Output Channels
Full Protools Plug-In Capability
18 Channels of Protools Recording and Playback
Support Equipment:
1 Sony CDP D-12 CD Player
1 TC Electronic M-300 Multi-Effects Unit
1 White 1/3 Octive Analyzer
House Sound System: ATM Flown Stereo System with Delayed Fills
1 BSS Omnidrive for 4-way Stereo System
2 Ashly Protea 4.24G - 4 chan. graphic EQ
1 Ashly Protea 2.24GS - 2 chan. graphic EQ
1 Ashly Protea 4.24RD - Graphic EQ Remote Control
1 Crest CA6 for high end
1 Crest CA9 for mids
1 Crest CA12 for lows
1 Crest CA 18 for subs
6 EAW KF650ie Full range speakers
4 EAW KF600 Sub speakers
2 EAW JF 80 Front Fills
5 EAW JF 60 Under Balcony Delays
4 EAW JF 60 speakers for stage lip fill
and image enhancement
5 JBL 6290 Stereo Power Amps
2 JBL 6260 Stereo Power Amps
Stage Monitor System:
Monitor Mixing Console: Soundcraft Series 5
40 Mono mic/line Input Channels
4 Stereo mic/line Input Channels
8 Subgroups, 16x10 output matrix
10 VCA Groups with PFL, Stereo AFL
3 Main outputs with true LCR panning
12 Aux outputs with on/off & pre/post switching
8 mute groups plus 256 MIDI controllable snapshots
Support Equipment:
40 Channel XTA Active Microphone Splitter
3 Klark-Teknik DN 360 Sereo Graphic EQ
1 Klark-Teknik DN 300 Graphic EQ
3 BSS Stereo Graphic EQ
1 Lexicon MPX 100 Multi Processor
1 Yamaha SPX 2000 Multi Processor
10 Mackie C-300 Monitor Speakers
2 Mackie SRM-450 Self-powered monitors
2 Mackie SRM-150 Self-powered Hot Spot Monitors
3 Galaxy Hotspot Monitors
House & Page Monitor:
Audio monitor to all dressing rooms, greenroom, control areas, production
areas and lobby.
Page capability to backstage areas and/or lobby
Production Line[I-com]
Clear-com 2 channel system
29 locations including all key control areas
Headsets: Assorted Handsets, Beltpacks, headsets and 2 Call light boxes
Microphone/Tie Lines
40 mic lines to stage[24 DSL and 16 USC] A inputs on Series 5, split
to SL for monitors.
32 mic lines to orchestra pit-B inputs on Series 5
5 mic lines to fly floors
10 mic lines to catwalks
8 mic lines to box seats
31 mic lines to various house locations
2 mic lines to lobby
48 tie lines from main control to upstage wall next to cable conduits
to dock
Microphone Inventory:
2 ATM 4033
6 AKG C-452/CK-1
1 AKG C-451/CK-1
3 AKG CK-8
6 AKG -10db Pads
2 AKG C-414 EB
1 AKG D-112
1 Beyer Dynamic M-88 TG
1 Earthworks SRO Test Microphone
2 Neumann KM 184
1 Senn MKE II-3
2 Senn MD 421
1 Senn MD 431
1 Shure SM 10A Headset mic
1 Shure Beta 52
3 Shure Beta 58
2 Shure Beta 91
3 Shure Beta 98
6 Shure KSM 9
2 Shure KSM 137
7 Shure SM 57
8 Shure SM 58
5 Shure SM 85
2 Shure SM 86
3 PCC-160
4 Whirlwind IMP DI-passive
8 BSS Ar-133 DI
Misc.
1 16 channel mic snake/stage box 100'
1 16 channel mic Splitter with two 50' tails,
unit is transformerless with ground lift switches on each channel
1 Rane Electronic 2 way crossover
5 JBL 4612OK wideband fill speakers